Sale

Edwards Passive Gauge Controller PGC201 PGC202

Starting at: $5,008.00 Starting at: $4,882.80

Edwards Passive Gauge Controller PGC201 PGC202

The Edwards range of passive gauges comprises of Pirani, Penning and both Bayard-Alpert and Extractor Ion gauge heads which together can measure from atmosphere down to 10-12 mbar. These are used in conjunction with a Passive gauge controller (PGC) to display pressure and offer an intuitive interface for the user alongside the ability to control remotely. Edwards will offer 2 controller variants; the PGC201 which covers the Pressure range of 10-9 to 1000 mbar, in conjunction with Pirani and Penning gauges, and the PGC202 which covers the wider range of and 10-12 to 1000 mbar when used with a Pirani and Ion gauge.

*Supplied with EU and USA Line Cord

Original price was: $5,008.00.Current price is: $4,882.80.
Passive Pirani/Penning
SKU: D03000400
Original price was: $5,428.00.Current price is: $5,292.30.
Passive Pirani/Ion
SKU: D03000410
View cart

Description

Edwards Passive Gauge Controller PGC201 PGC202

The Edwards range of passive gauges comprises of Pirani, Penning and both Bayard-Alpert and Extractor Ion gauge heads which together can measure from atmosphere down to 10-12 mbar. These are used in conjunction with a Passive gauge controller (PGC) to display pressure and offer an intuitive interface for the user alongside the ability to control remotely. Edwards will offer 2 controller variants; the PGC201 which covers the Pressure range of 10-9 to 1000 mbar, in conjunction with Pirani and Penning gauges, and the PGC202 which covers the wider range of and 10-12 to 1000 mbar when used with a Pirani and Ion gauge.

*Supplied with EU and USA Line Cord

· Universal pressure monitoring of high vacuum pump systems: turbomolecular, diffusion, cryogenic, ion etc.

· Annealing, melting, brazing and hardening furnaces

· Coating systems

· Analytical instrumentation

· Deployment in thermal radiation resistant and degassable systems is possible

· Particle accelerators

Additional information

Weight N/A
Edwards PGC

,

Brand

Edwards

Edwards is a leading developer and manufacturer of sophisticated vacuum products, abatement solutions and related value-added services.
Units Pirani/Penning Controller PGC201 Pirani/Ion Controller PGC202
Number of measurement channels 3 3
Measurement range Channel 1, 2 (PRG) mbar (Torr) 5 x 10-4 to 1000 5 x 10-4 to 1000
Channel 3 (CPG) (3.5 x 10-4 to 750) (3.5 x 10-4 to 750)
Channel 3 10-9 to 10-2
(IG40 BA)  (10-9 to 10-2) 2 x 10-11 to 1 x 10-2
(IG40 EX) (1.5 x 10-11 to 0.75 x 10-2)
2 x 10-12 to 1 x 10-4
(1.5 x 10-12 to 0.75 x 10-4)
Unit of measurement (selectable) mbar, Torr, Pa mbar, Torr, Pa
Measurement uncertainty
PRG ≤20% of the measured value ≤20% of the measured value
in the range 10-3 to 10-2 mbar (± 20%) in the range 10-3 to 10-2 mbar (± 20%)
in the range 10-2 to 102 mbar (± 15%) in the range 10-2 to 102 mbar (± 15%)
CPG ± 30% of the measured value in
the range 10-8 to 10-4 mbar
IG40 BA/EX +/- 2% of the measured value
Measurement cable m up to 50 up to 50
(application dependent) (application dependent)
Display for measured values digital, 7 segment LED, 4 digit mantissa and 2 digit exponent digital, 7 segment LED, 4 digit mantissa and 2 digit exponent
Type of gas (selectable) factor adjustable factor adjustable
Operating mode switching thresholds 2 per channel single, interval-trigger 2 per channel single, interval-trigger
Adjustable switching thresholds
PRG mbar (Torr) 5 x 10-3 to 500 5 x 10-3 to 500
(5 x 10-3 to 375) (5 x 10-3 to 375)
CPG mbar (Torr) 1 x 10-8 to 9.9 x 10-3
(0.75 x 10-8 to 7.4 x 10-3)
IG40 BA mbar (Torr) 1 x 10-8 to 5 x 10-3
(0.75 x 10-8 to 3.75 x 10-3)
IG40 EX mbar (Torr) 1 x 10-11 to 1 x 10-11
(0.75 x 10-11 to 0.75 x 10-11)
Switching relay hysteresis 10% of the trigger value (default), freely adjustable for PRG and CPG 10% of the trigger value (default), freely adjustable for PRG and IG40 BA or EX
Relay contact load rating a.c./d.c., max. 30 V/1 A a.c./d.c., max. 30 V/1 A
Chart recorder output (default)
PRG 0 to 10 V, log. divisions linear: 3 decades, 0 to 10 V, log. divisions linear: 3 decades,
approximately 10.5 V in case of a failure, approximately 10.5 V in case of a failure
logarithmic: (1 x 10-3 mbar), 1.67 V/decade logarithmic: (1 x 10-3 mbar), 1.67 V/decade
CPG logarithmic: (1 x 10-9 mbar), 1.43 V/ decade
IG40 BA or EX logarithmic: (1 x 10-12 mbar), 1.00 V/decade
Interface RS 232, RS 485 RS 232 C, RS 485
Mains connection 50/60 Hz V a.c. 100 – 240 100 – 240
Power consumption W < 10 < 60
Storage temperature range °C -20 to +60 – 20 to +60
Nominal temperature range °C +5 to +50 +5 to +50
Max. rel. humidity % n.c. 80 80
Weight kg (lbs) 1.4 (3.09) 1.4 (3.09)
Dimension (W x H x D) mm 106.4×128.4×174.5 106.4×128.4×184.5
Installation depth mm approx. 220 approx. 220
Protection class IP 40 40