Edwards ViV Vacuum Isolation Angle Valve
Starting at: $1,881.00 Starting at: $1,786.95
Edwards ViV Vacuum Isolation Angle Valve
Intended for use with nXDS, XDS, nXLi and nXRi dry primary pumps, the VIV vacuum isolation valve is a high conductance, fast acting high vacuum isolation valve that is designed to prevent the movement of vapor or particulates from the backing pump to the process chamber. When the VIV is closed, the backing pump is safely vented.
The VIV protects the process chamber from being vented when the pump stops or is stopped. When the backing pump is restarted, the valve will slowly open when the pressure within the VIV has dropped, minimizing the effects of any pressure burst.
Offered in AC or DC voltage versions.
- Description
- Additional information
- Brand
- Technical Specs
- Downloads
Description
Edwards ViV Vacuum Isolation Angle Valve
Intended for use with nXDS, XDS, nXLi and nXRi dry primary pumps, the VIV vacuum isolation valve is a high conductance, fast acting high vacuum isolation valve that is designed to prevent the movement of vapor or particulates from the backing pump to the process chamber. When the VIV is closed, the backing pump is safely vented.
The VIV protects the process chamber from being vented when the pump stops or is stopped. When the backing pump is restarted, the valve will slowly open when the pressure within the VIV has dropped, minimizing the effects of any pressure burst.
Offered in AC or DC voltage versions.
· VIV valves have high conductance Does not restrict primary pump performance
· Fast closing action Prevents migration of vapour or particulates from the backing pump to the process chamber
· Power failure protection Prevents process chamber venting in the event of a power supply failure
· Flexible installation options For Edwards backing pumps fitted with the M8 valve connector or the 15 way D Type logic interface connector, Edwards recommends the use of 24V dc valves and optional accessory cable or VIV
Additional information
| Weight | N/A |
|---|---|
| Edwards ViV Angle Valve | VIV KF25 100-115VAC, VIV KF25 208-230VAC, VIV KF25 24VDC, VIV KF40 24VDC, VIV KF40 100-115VAC, VIV KF40 208-230VAC, VIV KF50 24VDC |
Brand
| Flange type | NW25 | NW40 | NW50 | ||
| Operating pressure range | mbar | 1×10-8 to 1000 | 1×10-8 to 1000 | 1×10-8 to 1000 | |
| Conductance | Is-1 | 11 | 30.5 | 126 | |
| Electrical supply options | 24V d.c. | ü | ü | ü | |
| 100-115V a.c. | ü | ü | |||
| 208-230V a.c. | ü | ü | |||
| Differential pressure | Closing | mbar | >200 | ||
| Opening | mbar | <200 | |||
| Leak tightness | Body | mbar Is-1 | <1×10-9 | ||
| Across valve seat | mbar Is-1 | <1×10-5 | |||
| Pilot valve | mbar Is-1 | <1×10-7 | |||
| Switching times | For opening | s | <15* | ||
| For closing | s | <0.1 | |||
| Response time | s | <0.05 | |||
| Material | Body | Aluminium | |||
| Seals | Fluoroelastomer | ||||