Pfeiffer ASM 392 High Performance Mobile Leak Detector
Starting at: $78,112.80 Starting at: $75,769.42
Pfeiffer ASM 392 High Performance Mobile Leak Detector
The ASM 392 provides unrivalled performances with high sensitivity and accuracy. Sharing the same platform as the ASM 390 and equipped with an additional turbopump, the ASM 392 will speed up your leak detection process, without any compromise on footprint and maneuverability.
- Dry and clean pump with high backing pump capacity (35 m3 /h)
- Special pump architecture to deliver high helium pumping speed and extremely fast response times
- Slim design and high maneuverability
- Large color touch screen, fully rotatable and detachable without any tool
- Integrated toolbox for storing accessories
Inquire for Lead Time
- Description
- More Information (don't edit)
- Additional information
- Brand
- Technical Specs
- Dimensions
- Accessories
Description
Pfeiffer ASM 392 High Performance Mobile Leak Detector
The ASM 392 provides unrivalled performances with high sensitivity and accuracy. Sharing the same platform as the ASM 390 and equipped with an additional turbopump, the ASM 392 will speed up your leak detection process, without any compromise on footprint and maneuverability.
- Dry and clean pump with high backing pump capacity (35 m3 /h)
- Special pump architecture to deliver high helium pumping speed and extremely fast response times
- Slim design and high maneuverability
- Large color touch screen, fully rotatable and detachable without any tool
- Integrated toolbox for storing accessories
Inquire for Lead Time
Pfeiffer ASM 392 High-Performance Mobile Leak Detector
Boost leak testing throughput with the Pfeiffer ASM 392—a mobile, high-performance helium leak detector engineered for cleanroom and production environments where speed, sensitivity, and reliability matter. Whether you’re qualifying vacuum chambers, troubleshooting process lines, or doing routine maintenance on tools and fixtures, the ASM 392 delivers fast evacuation and rapid response so you can find and fix leaks sooner and get your equipment back online.
Key Advantages at a Glance
- Rapid pump-down & response: Special pump architecture provides high tracer-gas pumping speed for short cycle times on large test objects.
- Clean, dry pumping path: Oil-free operation supports ultra-clean applications and reduces routine maintenance.
- High maneuverability: Slim, ergonomic, cart-style design moves easily between stations without sacrificing performance.
- Operator-friendly interface: Large color touch screen is fully rotatable and detachable for convenient positioning at the test point.
- Ready for production: Integrated work surface and toolbox keep probes, adapters, and accessories within reach.
- Robust connectivity: Remote I/O and digital interfaces (e.g., RS-232/Ethernet options) support automation, data capture, and SPC.
- Backed by High Vac Depot: Expert guidance, ordering support, and leak detector rental options to cover spikes in demand.
Where the ASM 392 Excels
This platform is built for demanding, high-throughput leak testing in semiconductor and display manufacturing, large-area coatings, accelerators and research labs, aerospace, medical devices, and general vacuum component QA. If your workflow calls for frequent connect/disconnect cycles, tight pass/fail limits, or testing of sizable volumes, the ASM 392 helps shorten takt time while maintaining measurement integrity.
Technical Highlights (What Matters on the Floor)
- High-capacity dry backing pump for swift roughing and clean operation in sensitive environments.
- High helium pumping speed to minimize lag between tracer application and signal response—ideal for large chambers and complex plumbing.
- Dual-stage turbomolecular architecture (model-dependent) that speeds stabilization and recovery.
- Detachable touchscreen lets the operator monitor signals from the optimal vantage point—no more squinting from across the tool.
- Production-oriented design: integrated shelf/work surface, organized storage, easy service access, and fast contamination recovery procedures.
Need a slightly leaner configuration? Compare with the Pfeiffer ASM 390—the same mobile platform with a simplified pumping package for less demanding duty cycles.
Optimize Your Leak-Test Workflow
Pair the ASM 392 with the right accessories to maximize repeatability and operator efficiency:
- Leak detector accessories such as sniffer probes, carts, remote controls, filters, and adapters.
- Helium leak detector category for alternative models and complementary instruments.
- Short-term rentals to cover maintenance turnarounds, audits, or capacity surges.
Best-Practice Tips for Finding Leaks Faster
- Stabilize the system: Allow temperature and pressure to settle before testing to reduce false positives and drift.
- Start big, then zoom in: Verify gross integrity (blank-off tests) prior to localized spraying or sniffing. This shortens total debug time.
- Control tracer gas: Use consistent helium concentration and flow; shield from drafts to avoid diluting the signal.
- Document & compare: Log background, peak signal, and location for each test so you can trend performance over time.
Frequently Asked Questions
Is the ASM 392 suitable for cleanroom use?
Yes. Its oil-free, dry pumping path and enclosed layout are designed for clean environments and low maintenance.
Can I integrate the detector with my existing test stand?
In most cases, yes. The platform offers remote I/O and serial/ethernet options so you can trigger tests, capture data, and enforce pass/fail logic from your PLC or MES.
What if I only need a detector for a short project?
High Vac Depot offers weekly and monthly leak-detector rentals so you can scale capacity without a long-term capital commitment.
Why Buy from High Vac Depot?
High Vac Depot specializes in industrial and laboratory vacuum solutions—from pumps and gauges to complete helium leak-detection setups. Our team can help you size the right instrument, select compatible accessories, and plan for consumables and maintenance so your line keeps moving. If you’re migrating from another detector or expanding a station, we’ll recommend drop-in fittings and workflow tweaks to shorten your learning curve.
Get Pricing & Expert Help
Have questions about test method, throughput, or compliance? Contact the High Vac Depot team for application-specific guidance, lead-time details, and a tailored quote for your ASM 392 system with accessories.
{
“@context”:”https://schema.org”,
“@type”:”FAQPage”,
“mainEntity”:[
{
“@type”:”Question”,
“name”:”Is the ASM 392 suitable for cleanroom use?”,
“acceptedAnswer”:{“@type”:”Answer”,”text”:”Yes. Its oil-free, dry pumping path and enclosed layout are designed for clean environments and low maintenance.”}
},
{
“@type”:”Question”,
“name”:”Can I integrate the detector with my existing test stand?”,
“acceptedAnswer”:{“@type”:”Answer”,”text”:”In most cases, yes. The platform offers remote I/O and serial/ethernet options so you can trigger tests, capture data, and enforce pass/fail logic from your PLC or MES.”}
},
{
“@type”:”Question”,
“name”:”What if I only need a detector for a short project?”,
“acceptedAnswer”:{“@type”:”Answer”,”text”:”High Vac Depot offers weekly and monthly leak-detector rentals so you can scale capacity without a long-term capital commitment.”}
}
]
}
Additional information
| Weight | N/A |
|---|---|
| ASM 392 | RS-232 with Exhaust Filter, RS-232 with KF25, RS-232 with KF40, RS-232 + USB with Exhaust Filter, RS-232 + USB with KF25, RS-232 + USB with KF40, RS-232 + USB + Ethernet with Exhaust Filter, RS-232 + USB + Ethernet with KF25, RS-232 + USB + Ethernet with KF40 |
Brand
| Backing pump | With oil-free backing pump | |
| Connection flange (in) | DN 40 ISO-KF | |
| Detectable gases | 4He | |
| 3He | ||
| H2 | ||
| Dimensions (L x W x H) | 1,072 x 455 x 1,025 mm | 42.2 x 17.91 x 40.35 inch | |
| Exhaust connection | Exhaust with filter | |
| I/O interfaces | RS-232 | |
| Input voltage(s) | 100 – 240 V AC, 50/60 Hz | |
| Interface: Connection, device side | Standard 15 pins I/O | |
| Mains frequency compatibility | 50 Hz | |
| 60 Hz | ||
| Minimum detectable leakage rate for helium (sniffing leak detection) | 1 · 10-9 Pa m3/s | 7.5 · 10-9 Torr l/s | 1 · 10-8 mbar l/s | |
| Minimum detectable leakage rate for helium (vacuum leak detection) | 1 · 10-13 Pa m³/s | |
| Operating temperature | 10-35 °C | 50-95 °F | 283-308 K | |
| Power consumption | 800 W | |
| Power consumption max. | 1600 W | |
| Pumping speed backing pump | 35 m³/h | 20.6 cfm | 583.33 l/min | |
| Pumping speed for He | 25 l/s | |
| Sound pressure level | ≤55 dB(A) | |
| Start-up time (20°C) | 2 min | |
| Test method | Vacuum leak detection | |
| Sniffing leak detection | ||
| Type | High performance – mobile | |
| User interface | Graphic color touch screen (detachable) | |
| Weight | 130 kg | 286.6 lb |